| Sign In | Join Free | My autochinanet.com | 
 | 
Brand Name : ESTEL
Model Number : GPE48150G
Certification : ISO9001, CE, 3C, FCC, TLC
Place of Origin : Shenzhen, China (Mainland)
MOQ : 1
Price : 715-4286 usd
Payment Terms : L/C, D/A, D/P, , T/T, Western Union
Supply Ability : 20,000 sets per month
Delivery Time : 7-10 working days
Packaging Details : carton/wooden case
Power Factor : 0.98
Input Frequency : 45~65Hz
Application : outdoor power cabinet
Feature : hot-swappable
Installation Mode : 19” rack
Input Voltage : AC220V
Battery Charge Function Telecom Rectifier System Hot Swappable ISO9001 CE Certification
Quick Details:
| Place of Origin: Shenzhen, China (Mainland) | Input Voltage: AC220V | 
| Brand Name: ESTEL | Output Voltage: DC48V | 
| Model Number: GPE48150G | Output current:150A | 
| Product Name: Telecom Rectifier System | Input Frequency 45~65Hz | 
| Certification: ISO9001, CE, 3C, FCC, TLC | Max. Input Current: 50A | 
| Installation Mode: embedded | Power Factor: 0.98 | 
| Application: outdoor power cabinet | Components: 5×30A rectifier module, 1×monitoring module, power distribution | 
Payment & Shipping Terms:
| Minimum Order Quantity: | 1 set | 
| Price: | negotiation | 
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union | 
| Supply Ability: | 20,000 sets per month | 
| Delivery Time: | 7-10 working days | 
| Packaging Details: | carton/wooden case | 
1. GPE48150G System Configuration
The system consists of distribution unit, rectifier module (1 min.,5 set max.) and monitoring module. The configuration is optional, as following table:
| Configuration | Rectifier Module | Monitoring Module | Distribution | Remark | 
| Standard | GPR4830A1 / GPR4830A | GPM48D-232(With RS232 Port) | AC distribution: 1-phase, 3-wire input, 1-pole AC MCB(63A); DC distribution: Battery fuse 100A×1; LVLD: 63A×3 LVBD: 10A×2 | For details, please refer to the specifications of modules. | 
| Optional 1 | GPR4810A1 | GPM48D(without Ethernet port) | ||
| Optional 2 | GPR4815A | |||
| Optional 3 | GPR4820A | 
AC mains is first input AC-INPUT MCB and then fed into the rectifier module after the SPD and EMI filtering. AC-INPUT acts as protection to over load and short circuit to AC power. The LOAD1-,LOAD2-,LOAD3-,LOAD4-,LOAD5- link in series to 2 power-off contactors KM1,KM2.The user’s battery is connected to the DC output side through MCB BAT and KM2, and the MCB provides disconnection control, over-load and short-circuit protection to the battery.
Under normal conditions, every parameter of rectifier modules and distribution unit are controlled by the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains fault, the battery will power to the system. With the battery discharge, the terminal voltage of the battery starts to descend. When the voltage is under -47V±0.5V, the monitor reports DC under voltage alarm signal and when the voltage is under -46.0V±0.5V (adjustable), the KM1cuts off LOAD3-,LOAD4-,LOAD5- and retaining power to LOAD1-,LOAD2-. If the voltage drops to -43.0V±0.5V (adjustable), the KM2 will cut off output of LOAD1-,LOAD2- and then the power system will stop working. If the external AC mains recovers, the system will normally work again. (All above monitoring data are system default values and can be reset by user).
 Except for battery over-discharge protection, battery or load over-temperature protection is prohibitive under default setting, users can send command to activate or inactivate according to the demanding. To avoid the thunder and thunder surge pulse current break the power system, and match to the thunder protection module ideally, we must load decoupler on output port independently or keep some length cable.
| Input | |||||
| Parameter | Min. | Typical | Max. | Unit | Remark | 
| Input voltage range | 90 | 220 | 280 | Vac | |
| Input frequency | 45 | 50 | 65 | Hz | |
| Input current | 50 | A | |||
| Power factor | 0.98 | ||||
| Output | |||||
| Parameter | Min. | Typical | Max. | Unit | Remark | 
| Output voltage range | -42 | -53.5 | -58 | Vdc | |
| Output current range | 0 | 150 | A | 176~280VAC | |
| 0 | 75 | A | 90~<176VAC | ||
| Ripple (Vp-p) | 200 | mV | Rated input/output, apply 0.1uF film capacitor and 10uF high frequency electrolyte capacitor, oscilloscope band width of 20MHz. | ||
| Output efficiency | 90 | 92 | % | 220Vac input | |
| 83 | 85 | % | 110Vac input | ||
| Regulation | ±1 | % | |||
| Load regulation | ±1 | % | |||
| Line regulation | ±1 | % | |||
| Insulation rating | ||
| Parameter | Requirement | Remark | 
| Input - output | 2121 Vdc | |
| Input-chassis | 2121 Vdc | |
| Output - chassis | 750 Vdc | |
| Insulation resistance | @ normal atmospheric pressure, relative humidity: 90% Testing voltage: 500v dc insulation of input-output, input-ground, output-ground shall not be less than 10MΩ | |
| Environment | |||||
| Parameters | Min | Typ. | Max | Unit | Remark | 
| Operating temp | -25 | 55 | °C | For temperature≥55°C, output with power derating | |
| Storage tempStorage temperature | -40 | 80 | °C | ||
| Humidity | 10 | 90 | % | Relative humidity, no condensing | |
| Atmospheric pressure | 70 | 106 | KPa | ||
| Altitude | 0 | 3000 | m | ||
| Cooling method | Cooled by fan | ||||
| Waterproof and dustproof | In the following condition, the equipment can work normally:5um diameter greater than the dust concentration is less than or equal to 3 × 104 /m3,The dust particles are not conductive, magnetic and corrosion;Not waterproof. | ||||
| Notes: (1) when the system working temperature at 55℃~65℃,the rectifier power automatic derating; when 65℃, 176~280 Vac range capable of long-term regulated output at least 80% rated power; (2) when 55 ℃ ,the rectifiers can be output maximum power and normal operation, not over temperature protection and parts stress meet the requirements.; (3) Because of the characteristics of liquid crystal, liquid crystal work beyond the temperature range, the screen may appear bright or dark no display case; (4) A large number of dust entering the rectifiers, may cause internal short circuit and over temperature protection. Therefore, in the dust more places, please note that dust control measures, and regular cleaning dust-proof net and the rectifiers internal dust.. | |||||
| Mechanical specifications | |
| Dimensions (Overall) | 482.6mm×253.0mm×130.5mm | 
| Weight(kg)(Overall) | ≤18.5kg(Inclusive of module) ≤8.5kg( Frame + Distribution, exclusive of module) | 



Chassis connects with external electric through system interface board. As shown in figure below:

Cable connetors descriptions:
(1) N is the natural wire, L is the live wire,PE is the ground wire
(2) B1- and B2- is the BATT (-),B1+ and B2+ is the BATT (+)
(3) 1-,2-,3-,4-,5- are LODA1, LODA2…LODA5 load (-)
(4) 1+,2+,3+,4+,5+ are LOAD1, LOAD2…LOAD5 load (+)
(1) Small scale program controlled exchanges
(2) Access network
(3) Transmission equipment
(4) Mobile communication
(5) Satellite communication ground station
(6) Microwave communication
6. Features
(1) Adoption of active power factor compensation technology with factor >0.98
(2) Wide operating range of AC input voltage: 90~280Va
(3) Operating temperature range: -25°C~+55°C
(4) Zero current/voltage switching tech with high efficiency ≥92%
(5) Perfect battery management prolongs battery lifetime: charge/discharge management, battery temperature compensation, battery capacity test, low-voltage protection
(6) Hot-swappable
(7) Input under/over voltage protection
(8) Output over voltage protection
(9) Output over current protection
(10) Output short circuit protection
(11) Auto current sharing, parallel operation
(12) Embedded mounted
(13) Perfect surge protection function 20KA (8/20 US)
7. Packing and Shipping
 
 
 Our Delivery Agent
 
 The goods can be shipped by sea, by air, by courier, by land, by train, etc.
 Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.
 
 8. Our Contact Information
 
 Mobile Phone: 0086-13752765943
 Telephone: 0086-0755 66600941
Email: info@estel.com.cn
           lxf.estel@hotmail.com
 Skype: fiona.liang10
|   | 
| Battery Charge Function Telecom Rectifier System Hot Swappable ISO9001 CE Certification Images | 
 Waterproof Sinlgle Wall Outdoor Power Battery Cabinet / IP55 Outdoor Telecom
                                                                                    
                        
                        
                        
                                                            Waterproof Sinlgle Wall Outdoor Power Battery Cabinet / IP55 Outdoor Telecom
                                                    
                        
                     Sandwich Panel Outdoor Power Supply Cabinet Galvanized Steel Climate Controlled
                                                                                    
                        
                        
                        
                                                            Sandwich Panel Outdoor Power Supply Cabinet Galvanized Steel Climate Controlled
                                                    
                        
                     IP55 Outdoor Power Cabinet Three Bay Telecommunications Shelter With Air
                                                                                    
                        
                        
                        
                                                            IP55 Outdoor Power Cabinet Three Bay Telecommunications Shelter With Air
                                                    
                        
                     Heat Insulation Outdoor Power Cabinet , WeatherProof Power Supply Cabinet
                                                                                    
                        
                        
                        
                                                            Heat Insulation Outdoor Power Cabinet , WeatherProof Power Supply Cabinet
                                                    
                        
                     Sandwich Structure Panel Outdoor Power Cabinet For 19 Inch Equipment Battery
                                                                                    
                        
                        
                        
                                                            Sandwich Structure Panel Outdoor Power Cabinet For 19 Inch Equipment Battery
                                                    
                        
                     Customizable Indoor Power Distribution Cabinet For Data Centers And Power Supply
                                                                                        
                                                        
                        
                        
                        
                                                            Customizable Indoor Power Distribution Cabinet For Data Centers And Power Supply
                                                    
                        
                     8U Hot Pluggable Telecom Rectifier System For Indoor Cabinet With Wide Input
                                                                                    
                        
                        
                        
                                                            8U Hot Pluggable Telecom Rectifier System For Indoor Cabinet With Wide Input
                                                    
                        
                     Pole Mount Outdoor Power Cabinet IP55 One Front Door 1000VA Backup Power Supply
                                                                                    
                        
                        
                        
                                                            Pole Mount Outdoor Power Cabinet IP55 One Front Door 1000VA Backup Power Supply
                                                    
                        
                     Outdoor 19 Inch Rack Cabinet Battery Power Integrated Control Cabinet
                                                                                    
                        
                        
                        
                                                            Outdoor 19 Inch Rack Cabinet Battery Power Integrated Control Cabinet
                                                    
                        
                     Double Wall Galvanized Steel Outdoor Power Cabinet Rectifier System Enclosure
                                                                                    
                        
                        
                        
                                                            Double Wall Galvanized Steel Outdoor Power Cabinet Rectifier System Enclosure